Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[68169], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=A power consumption limit was configured, resulting in inadequate system power supply.)
Physical entity failed.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwEntityInvalid |
Trap OID |
1.3.6.1.4.1.2011.5.25.129.2.1.9 |
MIB |
HUAWEI-BASE-TRAP-MIB |
Alarm ID |
0x08130055 |
Alarm Name |
hwEntityInvalid |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
Parameter | Description |
---|---|
BaseTrapSeverity |
To describe the level of trap. |
ProbableCause |
To describe the probable cause of trap. |
BaseTrapEventType |
To describe the type of trap. |
EntityPhysicalIndex |
The index of the physical entity. |
EntContainedIn |
The value of entPhysicalIndex for the physical entity. |
EntPhysicalName |
The textual name of the physical entity. |
RelativeResource |
This object may contain a key word to indicate the relative resource of an entity. |
ReasonDescription |
To describe the reason of trap in DisplayString style. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.129.1.1 |
hwBaseTrapSeverity |
- |
1.3.6.1.4.1.2011.5.25.129.1.2 |
hwBaseTrapProbableCause |
- |
1.3.6.1.4.1.2011.5.25.129.1.3 |
hwBaseTrapEventType |
- |
1.3.6.1.2.1.47.1.1.1.1.4 |
entPhysicalContainedIn |
entPhysicalIndex |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.129.1.4 |
hwBaseTrapRelativeResource |
- |
1.3.6.1.4.1.2011.5.25.129.1.5 |
hwBaseTrapReasonDescr |
- |
1. Check whether the power modules configured are adequate for the system.
2. Check whether the power consumption limit configured is too low for system power supply. Reconfigure the capping power of the power supply. Then, check whether the alarm is cleared.
3. Insert the power module and check whether the alarm is cleared.
4. Collect trap, log, and configuration information, and contact technical support.
5. End.