Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[68051], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=The Lanswitch chip on the board failed.)
The control channel between physical entities is faulty.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwEntityInvalid_S |
Trap OID |
1.3.6.1.4.1.2011.5.25.129.2.1.9 |
MIB |
HUAWEI-BASE-TRAP-MIB |
Alarm ID |
0x08130055 |
Alarm Name |
hwEntityInvalid |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
Parameter | Description |
---|---|
BaseTrapSeverity |
To describe the level of trap. |
ProbableCause |
To describe the probable cause of trap. |
BaseTrapEventType |
To describe the type of trap. |
EntityPhysicalIndex |
The index of the physical entity. |
EntContainedIn |
The value of entPhysicalIndex for the physical entity which 'contains' this physical entity. |
EntPhysicalName |
The textual name of the physical entity. |
RelativeResource |
This object may contain a key word to indicate the relative resource of an entity. |
ReasonDescription |
To describe the reason of trap in DisplayString style. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.129.1.1 |
hwBaseTrapSeverity |
- |
1.3.6.1.4.1.2011.5.25.129.1.2 |
hwBaseTrapProbableCause |
- |
1.3.6.1.4.1.2011.5.25.129.1.3 |
hwBaseTrapEventType |
- |
1.3.6.1.2.1.47.1.1.1.1.4 |
entPhysicalContainedIn |
entPhysicalIndex |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.129.1.4 |
hwBaseTrapRelativeResource |
- |
1.3.6.1.4.1.2011.5.25.129.1.5 |
hwBaseTrapReasonDescr |
- |
1. Check whether the board has been reset of powered off. If the board is not reset or powered off, and some services are normal, go to step 4.
2. Power off the board, and then power on the board.
3. If the alarm persists, go to step 4.
4. Contact Huawei technical support personnel.