DEVM_1.3.6.1.4.1.2011.5.25.129.2.2.11 hwVoltFallingAlarm-73216

Trap Buffer Description

SRM_BASE/2/VOLTFALLINGALARM: OID 1.3.6.1.4.1.2011.5.25.129.2.2.11 Voltage exceeded the lower prealarm limit. (EntityPhysicalIndex=[ULONG], EntityPhysicalIndex=[ULONG], BaseThresholdType=3, BaseThresholdEntityPhysicalIndex=[ULONG], BaseTrapSeverity=4, BaseTrapProbableCause=73216, BaseTrapEventType=6, EntPhysicalName=[STRING], BaseThresholdValue=[ULONG], BaseThresholdUnit=5, LowCritical=[ULONG], LowWarning=[ULONG])

The voltage of a physical entity exceeded the lower critical threshold.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwVoltFallingAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.129.2.2.11

MIB

HUAWEI-BASE-TRAP-MIB

Alarm ID

0x081300ab

Alarm Name

hwVoltFallingAlarm

Alarm Type

environmentalAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.129.2.2.12 hwVoltFallingResume-73216

Trap Buffer Parameters

Parameter Description

BaseTrapSeverity

Indicates the level of trap.

BaseTrapProbableCause

Indicates the possible cause of trap.

BaseTrapEventType

Indicates the type of trap.

EntityPhysicalIndex

Indicates the physical index.

EntPhysicalName

Indicates the textual name of the physical entity.

BaseThresholdValue

Indicates the actual value.

BaseThresholdUnit

Indicates the unit of the value (mV).

BaseThresholdLowCritical

Indicates the upper critical limit.

BaseThresholdLowWarning

Indicates the minor upper limit.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.129.1.1

hwBaseTrapSeverity

-

1.3.6.1.4.1.2011.5.25.129.1.2

hwBaseTrapProbableCause

-

1.3.6.1.4.1.2011.5.25.129.1.3

hwBaseTrapEventType

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.129.1.6.1.3

hwBaseThresholdValue

entPhysicalIndex

hwBaseThresholdType

hwBaseThresholdIndex

1.3.6.1.4.1.2011.5.25.129.1.6.1.4

hwBaseThresholdUnit

entPhysicalIndex

hwBaseThresholdType

hwBaseThresholdIndex

1.3.6.1.4.1.2011.5.25.129.1.6.1.5

hwBaseThresholdLowCritical

entPhysicalIndex

hwBaseThresholdType

hwBaseThresholdIndex

1.3.6.1.4.1.2011.5.25.129.1.6.1.6

hwBaseThresholdLowWarning

entPhysicalIndex

hwBaseThresholdType

hwBaseThresholdIndex

Impact on the System

Temporarily, services will not be interrupted but clearing this trap is urgent.

Possible Causes

Cause 1: The PDF power supply was insufficient.

Cause 2: The power supply module was faulty.

Procedure

1.Run the display voltage slot slot-id command in the user view to view the voltage of each board.

2.Check whether the PDF power supply is sufficient.

  • If so, go to Step 4.
  • If not, go to Step 3.

3.Increase the PDF power supply and check whether the trap is cleared.

  • If so, go to Step 6.
  • If not, go to step 4.

4. Replace the board and check whether the trap is cleared.

  • If so, go to Step 6.
  • If not, go to Step 5.

5. Collect the trap information, log information, and configuration of the router, and contact technical support personnel.

6. End.