SRM_BASE/2/VOLTRISINGALARM: OID 1.3.6.1.4.1.2011.5.25.129.2.2.9 Voltage exceeded the upper prealarm limit. (EntityPhysicalIndex=[ULONG], EntityPhysicalIndex=[ULONG], BaseThresholdType=3, BaseThresholdEntityPhysicalIndex=[ULONG], BaseTrapSeverity=6, BaseTrapProbableCause=72705, BaseTrapEventType=6, EntPhysicalName=[STRING], BaseThresholdValue=[ULONG], BaseThresholdUnit=5, HighWarning=[ULONG], HighCritical=[ULONG])
The voltage of a physical entity exceeded the upper critical threshold.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwVoltRisingAlarm |
Trap OID |
1.3.6.1.4.1.2011.5.25.129.2.2.9 |
MIB |
HUAWEI-BASE-TRAP-MIB |
Alarm ID |
0x081300aa |
Alarm Name |
hwVoltRisingAlarm |
Alarm Type |
environmentalAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.129.2.2.10 hwVoltRisingResume-72705 |
Parameter | Description |
---|---|
BaseTrapSeverity |
To describe the level of trap. |
BaseTrapProbableCause |
To describe the probable cause of trap. |
BaseTrapEventType |
To describe the type of trap. |
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalName |
The textual name of the physical entity. |
BaseThresholdValue |
Indicates the actual value. |
BaseThresholdUnit |
Indicates the unit of the value (mV). |
BaseThresholdHighWarning |
Indicates the minor upper limit. |
BaseThresholdHighCritical |
Indicates the upper critical limit. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.129.1.1 |
hwBaseTrapSeverity |
- |
1.3.6.1.4.1.2011.5.25.129.1.2 |
hwBaseTrapProbableCause |
- |
1.3.6.1.4.1.2011.5.25.129.1.3 |
hwBaseTrapEventType |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.129.1.6.1.3 |
hwBaseThresholdValue |
entPhysicalIndex hwBaseThresholdType hwBaseThresholdIndex |
1.3.6.1.4.1.2011.5.25.129.1.6.1.4 |
hwBaseThresholdUnit |
entPhysicalIndex hwBaseThresholdType hwBaseThresholdIndex |
1.3.6.1.4.1.2011.5.25.129.1.6.1.7 |
hwBaseThresholdHighWarning |
entPhysicalIndex hwBaseThresholdType hwBaseThresholdIndex |
1.3.6.1.4.1.2011.5.25.129.1.6.1.8 |
hwBaseThresholdHighCritical |
entPhysicalIndex hwBaseThresholdType hwBaseThresholdIndex |
1.Run the display voltage slot slot-id command in the user view to view the voltage of each board.
2.If the voltage of the board cannot be recovered, replace the board and then check whether the trap is cleared.
3.Collect the trap information, log information, and configuration of the router, and contact technical support personnel.
4.End.