The MAC-FCS-SD of signal alarm has occurred. (IfIndex=[hwPhysicalPortThrIfIndex],IfName=[hwPhysicalPortThrName],CurrentValue=[hwPhysicalPortCrcPerCurrentValueString],AlarmThreshold=[hwPhysicalPortCrcPerAlarmThresholdString],ResumeThreshold=[hwPhysicalPortCrcPerResumeThresholdString])
The MAC-FCS-SD of signal alarm.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwPhysicalPortCrcSd |
Trap OID |
1.3.6.1.4.1.2011.5.25.157.2.157.11 |
MIB |
HUAWEI-PORT-MIB |
Alarm ID |
0x00F10052 |
Alarm Name |
hwPhysicalPortCrcSd |
Alarm Type |
processingErrorAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.157.2.157.12 hwPhysicalPortCrcSdResume |
Parameter | Description |
---|---|
hwPhysicalPortThrIfIndex |
Index of physical port. |
hwPhysicalPortThrName |
Name of physical port. |
hwPhysicalPortCrcPerCurrentValueString |
Current bit error rate on a physical interface. |
hwPhysicalPortCrcPerAlarmThresholdString |
Alarm threshold for the bit error rate on a physical interface. |
hwPhysicalPortCrcPerResumeThresholdString |
Alarm clearance threshold for the bit error rate on a physical interface. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.157.1.14.1.1.1 |
hwPhysicalPortThrIfIndex |
hwPhysicalPortThrIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.14.1.1.2 |
hwPhysicalPortThrName |
hwPhysicalPortThrIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.14.1.1.29 |
hwPhysicalPortCrcPerCurrentValueString |
hwPhysicalPortThrIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.14.1.1.42 |
hwPhysicalPortCrcSdAlarmThresholdString |
hwPhysicalPortThrIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.14.1.1.43 |
hwPhysicalPortCrcSdResumeThresholdString |
hwPhysicalPortThrIfIndex |
1. Check whether the optical fiber is properly connected. The optical fiber has card fasteners. If you hear a click sound, the optical fiber is properly connected. Then, run the display this interface command to check whether the interface is Up.
2. Run the display this interface command in the interface view to check whether the receive optical power of the optical module is in the normal range.
3. Run the display this interface command in the interface view to check whether the two ends have the same configurations for the link negotiation mode, clock mode, and scramble mode.
4. Modify the configurations so that the two ends have the same link negotiation mode, clock mode, and scramble mode. Then, check whether the alarm is cleared.
5. Collect alarm information, log information and configuration information, and then contact technical support personnel.
6. End.