The local fault alarm has occurred. (IfIndex=[hwPhysicalPortIfIndex], IfName=[hwPhysicalPortName])
The local fault alarm.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwLocalFaultAlarm |
Trap OID |
1.3.6.1.4.1.2011.5.25.157.2.175 |
MIB |
HUAWEI-PORT-MIB |
Alarm ID |
0x081320c6 |
Alarm Name |
hwLocalFaultAlarm |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.157.2.176 hwLocalFaultAlarmResume |
Parameter | Description |
---|---|
hwPhysicalPortIfIndex |
Index of physical port. |
hwPhysicalPortName |
Name of physical port. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.1 |
hwPhysicalPortIfIndex |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.4 |
hwPhysicalPortName |
hwPhysicalPortIfIndex |
1.Check whether the optical fiber is faulty. If the optical fiber is working properly, go to Step 2. If the optical fiber is faulty, replace it. Then check whether the alarm is cleared.
2.Check whether the optical modules on both ends are faulty. If the optical modules on both ends are working properly, go to Step 3. If an optical module is faulty, replace it. Then check whether the alarm is cleared.
3.Check whether the board on the remote end is faulty. If the board is working properly, go to Step 4. If the board is faulty, replace it. Then check whether the alarm is cleared.
4.Collect alarm information, log information and configuration information, and then contact technical support personnel.