Loss of code group synchronization alarm.(hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex],SlotID=[hwPhysicalPortInSlot],CardID=[hwPhysicalPortInCard],PortID=[hwPhysicalPortInPort],InterfaceName=[hwPhysicalPortName])
Loss of code group synchronization alarm.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwLcdAlarm |
Trap OID |
1.3.6.1.4.1.2011.5.25.157.2.245 |
MIB |
HUAWEI-PORT-MIB |
Alarm ID |
0x0813008d |
Alarm Name |
hwPicLcdAlarm |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
Parameter | Description |
---|---|
hwPhysicalPortIfIndex |
Index of physical port. |
hwPhysicalPortInSlot |
Slot ID. |
hwPhysicalPortInCard |
Card ID. |
hwPhysicalPortInPort |
Port ID. |
hwPhysicalPortName |
Name of physical port. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.6 |
hwPhysicalPortInSlot |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.7 |
hwPhysicalPortInCard |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.8 |
hwPhysicalPortInPort |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.4 |
hwPhysicalPortName |
hwPhysicalPortIfIndex |
Cause 1: The SDH path connected to the interface failed to receive packets properly. For example, an hwLosAlarm, hwLofAlarm, hwLaisAlarm, hwAuLopAlarm, hwAuAisAlarm alarm was generated.
Cause 2: The SDH path received a large amount of error codes and a hwB1TcaAlarm, hwB2TcaAlarm or hwB3TcaAlarm alarm was generated.
Cause 3: The physical-layer processing chip on a subcard failed to function properly
1. Check and clear an hwLosAlarm, hwLofAlarm, hwLaisAlarm, hwAuLopAlarm, hwAuAisAlarm alarm generated for the SDH path connecting the upstream device and the interface. Check whether the alarm is cleared.
2. Check and clear a hwB1TcaAlarm, hwB2TcaAlarm or hwB3TcaAlarm alarm for the local device. Check whether the alarm is cleared.
3. Collect alarm information, log information and configuration information, and then contact technical support personnel.