The configured phy-number parameters did not match for the two connected FlexE physical interfaces.(hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex], hwPhysicalPortName=[hwPhysicalPortName], hwPhysicalPortLocalPhyNumber=[hwPhysicalPortLocalPhyNumber], hwPhysicalPortRemotePhyNumber=[hwPhysicalPortRemotePhyNumber])
The configured phy-number parameters did not match for the two connected FlexE physical interfaces.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwFlexEPhyNumberMismatch |
Trap OID |
1.3.6.1.4.1.2011.5.25.157.2.260 |
MIB |
HUAWEI-PORT-MIB |
Alarm ID |
0x00F101f8 |
Alarm Name |
hwFlexEPhyNumberMismatch |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.157.2.261 hwFlexEPhyNumberMismatchResume |
Parameter | Description |
---|---|
hwPhysicalPortIfIndex |
Index of physical port. |
hwPhysicalPortName |
Name of physical port. |
hwPhysicalPortLocalPhyNumber |
Local phy-number value. |
hwPhysicalPortRemotePhyNumber |
Remote phy-number value. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.1 |
hwPhysicalPortIfIndex |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.4 |
hwPhysicalPortName |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.33 |
hwPhysicalPortLocalPhyNum |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.34 |
hwPhysicalPortRemotePhyNum |
hwPhysicalPortIfIndex |
1.Configure phy-number parameters of the two connected FlexE physical interfaces be the same. Then check whether the alarm is cleared.
2.Collect alarm information, log information and configuration information, and then contact technical support personnel.
3.End.