DEVM_1.3.6.1.4.1.2011.5.25.157.2.272 hwFlexEPhyRemoteFaultAlarm

Trap Buffer Description

The remote fault alarm of FlexE physical interface has occurred.(hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex], hwPhysicalPortName=[hwPhysicalPortName])

The remote fault alarm of FlexE physical interface has occurred.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

hwFlexEPhyRemoteFaultAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.157.2.272

MIB

HUAWEI-PORT-MIB

Alarm ID

0x00F10213

Alarm Name

hwFlexEPhyRemoteFaultAlarm

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.157.2.273 hwFlexEPhyRemoteFaultAlarmResume

Trap Buffer Parameters

Parameter Description

hwPhysicalPortIfIndex

Index of physical port.

hwPhysicalPortName

Name of physical port.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.157.1.8.1.1.1

hwPhysicalPortIfIndex

hwPhysicalPortIfIndex

1.3.6.1.4.1.2011.5.25.157.1.8.1.1.4

hwPhysicalPortName

hwPhysicalPortIfIndex

Impact on the System

Services may be switched or interrupted.

Possible Causes

The remote FlexE physical interface has faults.

Procedure

1.Clear the FlexE local fault alarm of remote FlexE physical interface, Then check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 3.
  • If the alarm is not cleared, go to Step 2.

2.Collect alarm information, log information and configuration information, and then contact technical support personnel.

3.End.