The delay difference of FlexE physical interfaces in the same group is abnormal.(hwPhysicalIndex=[hwPhysicalIndex], hwPhysicalPortList=[hwPhysicalPortList])
The delay difference of FlexE physical interfaces in the same group is abnormal.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwFlexEPhyDelayOverAlarm |
Trap OID |
1.3.6.1.4.1.2011.5.25.157.2.276 |
MIB |
HUAWEI-PORT-MIB |
Alarm ID |
0x00F10210 |
Alarm Name |
hwFlexEPhyDelayOverAlarm |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.157.2.277 hwFlexEPhyDelayOverAlarmResume |
Parameter | Description |
---|---|
hwPhysicalIndex |
Physical Index. |
hwPhysicalPortList |
Physical interface List. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.1 |
hwPhysicalPortIfIndex |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.38 |
hwPhysicalPortList |
hwPhysicalPortIfIndex |
1.Use same fiber paths between the FlexE physical interfaces in the same group.Then check whether the alarm is cleared.
2.Collect alarm information, log information and configuration information, and then contact technical support personnel.
3.End.