DEVM_1.3.6.1.4.1.2011.5.25.157.2.296 hwEthTxFlowFallAlarm

Trap Buffer Description

Traffic fall alarm in the transmit direction of an Ethernet interface.(hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex], hwPhysicalPortName=[hwPhysicalPortName])

Traffic fall alarm in the transmit direction of an Ethernet interface.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwEthTxFlowFallAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.157.2.296

MIB

HUAWEI-PORT-MIB

Alarm ID

0X0801227A

Alarm Name

hwEthTxFlowFallAlarm

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.157.2.297 hwEthTxFlowFallAlarmResume

Trap Buffer Parameters

Parameter Description

hwPhysicalPortIfIndex

Index of physical port.

hwPhysicalPortName

Name of physical port.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.157.1.8.1.1.1

hwPhysicalPortIfIndex

hwPhysicalPortIfIndex

1.3.6.1.4.1.2011.5.25.157.1.8.1.1.4

hwPhysicalPortName

hwPhysicalPortIfIndex

Impact on the System

If the alarm exists, the traffic decreases sharply.

Possible Causes

When an interface is up, traffic fall monitoring is enabled. If the average traffic in the first two measurement periods is greater than 1 Mbit/s but the average traffic in the current measurement period is less than 10 kbit/s, it indicates that the traffic decreases sharply. In this case, a traffic fall alarm is generated. Each monitoring period is 2 minutes.

Procedure

The alarm is automatically cleared after the first 2-minute period elapses.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >