The chassis was removed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131073)
The chassis is removed, an alarm is generated.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwChassisRemove |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.1.1 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x08130001 |
Alarm Name |
hwChassisRemove |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
Parameter | Description |
---|---|
EntityPhysicalIndex |
Indicates the entity index. |
EntPhysicalIndex |
Indicates the entity index. |
EntPhysicalName |
Indicates the entity name. |
EntityTrapFaultID |
Indicates the error code. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.Insert the chassis and check whether the alarm is cleared.
2.Collect the trap information, log information, and configuration of the router, and contact technical personnel.
3.End.