DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.3 hwChassisFail-131344

Trap Buffer Description

The chassis failed partially. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131344, Reason=The switch 1 on the power panel is off.)

The chassis experienced a partial failure.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwChassisFail

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.1.3

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x081300b4

Alarm Name

hwChassisFail

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.4 hwChassisFailResume-131344

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the physical entity, such as chassis.

ReasonDescription

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

The power supply fault may lead to power supply insufficiency on the router and cause the board to reset due to power supply insufficiency. This indirectly affects services, and the problem needs to be resolved.

Possible Causes

The switch 1 on the power panel is off.

Procedure

1. Check whether switch 1 on the power panel is closed.

  • If switch 1 is not closed, go to Step 2.
  • If switch 1 is closed, go to Step 3.

2. Close switch 1 and check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 4.
  • If the alarm persists, go to Step 3.

3. Collect trap, log, and configuration information, and contact technical support.

4. End.