DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.3 hwChassisFail-131355

Trap Buffer Description

The chassis failed partially. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131355, Reason=The backplane ID of chassis failed to be checked.)

The chassis experienced a partial failure.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwChassisFail

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.1.3

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x081300b4

Alarm Name

hwChassisFail

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.4 hwChassisFailResume-131355

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the physical entity, such as chassis.

ReasonDescription

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

Some services may experience exceptions.

Possible Causes

The backplane ID of chassis failed to be checked.

Procedure

1. If an installed board has no services on it, check whether the board is properly installed, if pins have bent, and if the board connectors become faulty.

2. If the board is not securely installed, install it securely.

3. If the pins on the backplane have bent, do not install a new board into the improper slot, go to Step 6.

4. If only the board connectors are found to be faulty, replace the board.

5. If services on the board are normal, go to Step 6.

6. Collect trap, log, and configuration information, and contact technical support.

7. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.