The chassis failed partially. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131355, Reason=The backplane ID of chassis failed to be checked.)
The chassis experienced a partial failure.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwChassisFail |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.1.3 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x081300b4 |
Alarm Name |
hwChassisFail |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.4 hwChassisFailResume-131355 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
EntPhysicalName |
Indicates the name of the physical entity, such as chassis. |
ReasonDescription |
Indicates the description of the cause of the trap. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2 |
hwEntityOperStatus |
entPhysicalIndex |
1. If an installed board has no services on it, check whether the board is properly installed, if pins have bent, and if the board connectors become faulty.
2. If the board is not securely installed, install it securely.
3. If the pins on the backplane have bent, do not install a new board into the improper slot, go to Step 6.
4. If only the board connectors are found to be faulty, replace the board.
5. If services on the board are normal, go to Step 6.
6. Collect trap, log, and configuration information, and contact technical support.
7. End.