DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.5 hwChassisInvalid-131587

Trap Buffer Description

The chassis totally failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntityPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131587, Reason=The board types of the master and slave MPUs are different.)

The chassis totally failed.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwChassisInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.1.5

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x081300b5

Alarm Name

hwChassisInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.6 hwChassisInvalidResume-131587

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the physical entity, such as "chassis"

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

The slave MPU may fail to register.

Possible Causes

The board types of the master and slave MPUs are different.

Procedure

1. Install master and slave MPUs of the same board type.

2. If the alarm still exists, collect trap, log, and configuration information, and contact technical support personnel.

3. End.