The chassis totally failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntityPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131587, Reason=The board types of the master and slave MPUs are different.)
The chassis totally failed.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwChassisInvalid |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.1.5 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x081300b5 |
Alarm Name |
hwChassisInvalid |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.6 hwChassisInvalidResume-131587 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
EntPhysicalName |
Indicates the name of the physical entity, such as "chassis" |
Reason |
Indicates the description of the cause of the trap. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2 |
hwEntityOperStatus |
entPhysicalIndex |
1. Install master and slave MPUs of the same board type.
2. If the alarm still exists, collect trap, log, and configuration information, and contact technical support personnel.
3. End.