DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.5 hwChassisInvalid-131589

Trap Buffer Description

The chassis totally failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntityPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131589, Reason=Software Test Right license will expire. After it expires, the boards or cards will be reset once every 24 hours.)

The chassis totally failed.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwChassisInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.1.5

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x081300b5

Alarm Name

hwChassisInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.6 hwChassisInvalidResume-131589

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the physical entity, such as "chassis"

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

Software Test Right license will expire. After it expires, the boards or cards will be reset once every 24 hours.

Possible Causes

Software Test Right license will expire. After it expires, the boards or cards will be reset once every 24 hours.

Procedure

1. Check whether license control items are about to expire.

  • If they are about to expire, go to Step 2.
  • If they are not about to expire, go to Step 3.

2. Re-apply for and activate the license control items. Then, check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 4.
  • If the alarm persists, go to Step 3.

3. Collect alarm information, log information and configuration information, and then contact technical support personnel.

4. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >