DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.15 hwBrdTempFatalAlarm-143872

Trap Buffer Description

The board temperature exceeded the fatal alarm threshold. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName],EntityThresholdType=[EntityThresholdType], EntityThresholdCritical=[EntityThresholdCritical], EntityThresholdCurrent=[EntityThresholdCurrent], EntityTrapFaultID=143872, Reason=The board temperature was extremely high.)

Board temperature fatal alarm.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwBrdTempFatalAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.10.15

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x0813000b

Alarm Name

hwBrdTempFatalAlarm

Alarm Type

environmentalAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.16 hwBrdTempFatalResume-143872

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

To describe the fault id of trap.

EntPhysicalName

Indicates the name of the physical entity.

EntityThresholdType

The abnormal type for temperature:

1: hige.

2: low.

EntityThresholdCritical

The critical alarm threshold for critical alarm.

EntityThresholdCurrent

The current value that been measured.

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.5.1.1

hwEntityThresholdType

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.5.1.4

hwEntityThresholdCritical

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.5.1.3

hwEntityThresholdCurrent

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

Impact on the System

Services will not be affected, but a speedy solution is required.

Possible Causes

The board temperature was extremely high.

Procedure

1. Check if there are idle slots without filler panels on the device. If there are idle slots without filler panels, install filler panels to cover these slots.

2. Check if the filter screen of the fan module is clogged. If the filter screen is clogged, clean the filter screen.

3. Check the ambient temperature. If the ambient temperature is too high, reduce the temperature to a normal level.

4. Check if the fan module is faulty. If there is a fault on the fan module, rectify the fault first.

5. If the ambient temperature is normal but the alarm is still reported, the possible cause is that the module temperature is too high. In this case, collect the information about alarms, logs, and configurations, and then contact technical support personnel.

6. End.