The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132101,Reason=The supply voltage 48V of the board is abnormal.)
The board experienced a partial failure.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwBoardFail |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.2.3 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x08130054 |
Alarm Name |
hwBoardFail |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.4 hwBoardFailResume-132101 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
EntPhysicalName |
Indicates the name of the physical entity. |
EntityType |
Indicates the type of the physical entity. The value can be one of the following: -1: mpu(1) -2: lpu(2) -3: sfu(3) -4: pic(4) -5: cfcard(5) -6: ofc(6) -7: board(7) -255: other(255) |
Reason |
Indicates the description of the cause of the trap. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.2 |
hwEntityTrapEntType |
- |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.219.1.13 |
hwEntityTrapReasonDescr |
- |
1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2 |
hwEntityOperStatus |
entPhysicalIndex |
1. Run the display device command in the user view to check whether the device is installed with two power modules. If not, install the additional 48 V power module that is required to ensure normal power supply.
2. If the power supply for the board is abnormal and there is an alarm about faulty power modules, first handle the alarm. If the power supply for the board is normal but the alarm persists, go to Step 3.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.