DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.3 hwBoardFail-132108

Trap Buffer Description

The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132108,Reason=The clock signal of the clock board is abnormal)

The board experienced a partial failure.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwBoardFail

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.2.3

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08130054

Alarm Name

hwBoardFail

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.4 hwBoardFailResume-132108

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

-1: mpu(1)

-2: lpu(2)

-3: sfu(3)

-4: pic(4)

-5: cfcard(5)

-6: ofc(6)

-7: board(7)

-255: other(255)

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

Services on the board may be affected and even be interrupted. This problem must be solved immediately.

Possible Causes

The clock signal of the clock board is abnormal.

Procedure

1. Check whether the two main control boards are securely installed. If not, install the them securely.

2. If an installed board has no services on it, check whether the board is properly installed, pins have bent, and the board connectors are faulty.

3. If the board is not securely installed, install it securely.

4. If the pins on the backplane have bent, do not install a new board into the improper slot. Contact technical support.

5. If only the board connectors are found to be faulty, replace the board.

6. If service have run on the faulty board but the alarm persists, collect trap, log, and configuration information, and contact technical support.

7. End.