The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132109,Reason=The voltage exceeded the upper limit of the fatal threshold.)
The board experienced a partial failure.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwBoardFail |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.2.3 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x08130054 |
Alarm Name |
hwBoardFail |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.4 hwBoardFailResume-132109 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
EntPhysicalName |
Indicates the name of the physical entity. |
EntityType |
Indicates the type of the physical entity. The value can be one of the following: -1: mpu(1) -2: lpu(2) -3: sfu(3) -4: pic(4) -5: cfcard(5) -6: ofc(6) -7: board(7) -255: other(255) |
Reason |
Indicates the description of the cause of the trap. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.2 |
hwEntityTrapEntType |
- |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.219.1.13 |
hwEntityTrapReasonDescr |
- |
1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2 |
hwEntityOperStatus |
entPhysicalIndex |
1. If the power module fails, rectify the fault.
2. Run the display voltage slot slot-id command in the user view to check whether the actual voltage exceeds the upper critical threshold.
3. If the actual voltage exceeds the upper critical threshold, collect trap, log, and configuration information, and contact technical support.
4. End.