DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.3 hwBoardFail-132139

Trap Buffer Description

The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132139,Reason=The subcard voltage exceeded the upper limit of the fatal threshold.)

The board experienced a partial failure.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwBoardFail

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.2.3

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08130054

Alarm Name

hwBoardFail

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.4 hwBoardFailResume-132139

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

-1: mpu(1)

-2: lpu(2)

-3: sfu(3)

-4: pic(4)

-5: cfcard(5)

-6: ofc(6)

-7: board(7)

-255: other(255)

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

Subcard running is affected, and the subcard may even be restarted and services are interrupted.

Possible Causes

The voltage of the subcard exceeded the fatal upper threshold.

Procedure

1. Run the display voltage lpu slot slot-id command to check the voltage information about the subcards. If the fault cannot be rectified within a short period of time, replace the subcard.

2. If the alarm persists, collect trap, log, and configuration information, and contact technical support.

3. End.