DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.3 hwBoardFail-132155

Trap Buffer Description

The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132155,Reason=The link between the CMAC chip and the NP chip was detected faulty.)

The board experienced a partial failure.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwBoardFail

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.2.3

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08130054

Alarm Name

hwBoardFail

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.4 hwBoardFailResume-132155

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

-1: mpu(1)

-2: lpu(2)

-3: sfu(3)

-4: pic(4)

-5: cfcard(5)

-6: ofc(6)

-7: board(7)

-255: other(255)

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

Services on the board are affected and may even be interrupted. The problem must be solved immediately.

Possible Causes

The link between the CMAC chip and the NP chip was detected faulty.

Procedure

1. Reset the CMAC board. If the alarm persists, replace the board.

2. If the alarm persists, collect trap, log, and configuration information, and contact technical support.

3. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >