DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.3 hwBoardFail-132427

Trap Buffer Description

The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132427,The FPGA3 logic of the board is abnormal)

The board experienced a partial failure.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwBoardFail

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.2.3

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08130054

Alarm Name

hwBoardFail

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.4 hwBoardFailResume-132427

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

-1: mpu(1)

-2: lpu(2)

-3: sfu(3)

-4: pic(4)

-5: cfcard(5)

-6: ofc(6)

-7: board(7)

-255: other(255)

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

Services on the board are abnormal. This problem must be solved immediately.

Possible Causes

The FPGA3 logic of the board is abnormal.

Procedure

1. If the board is not reset or powered off and services are running properly, collect alarm, log, and configuration information and contact technical support. Otherwise, go to Step 2.

2. Power off the faulty board and then power it on again.

3. If the board cannot be registered or the alarm persists after the board is registered, replace the faulty board.

4. If the alarm persists, collect alarm, log, and configuration information and contact technical support.

5. End.