The board totally failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=132614, Reason=The EPLD logic of the board failed.)
The overall function of the board does not take effect.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwBoardInvalid |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.2.5 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x0813002e |
Alarm Name |
hwBoardInvalid |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.6 hwBoardInvalidResume-132614 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
EntPhysicalName |
Indicates the name of the entity such as a chassis. |
EntityType |
Indicates the type of the physical entity. The value can be one of the following:
|
Reason |
Indicates the description of the cause of the trap. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.2 |
hwEntityTrapEntType |
- |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.219.1.13 |
hwEntityTrapReasonDescr |
- |
1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2 |
hwEntityOperStatus |
entPhysicalIndex |
1. Go to Step 2 if the faulty board is not the main control board.
2. If the faulty board is registered, run the EPlD upgrade command in the user view: upgrade mpu/lpu/sfu slotid startup firmware. Then, go to Step 4.
3. If the faulty board is not registered, power off and then power on the faulty board.
4. If the faulty board cannot be registered or the fault persists after the board is registered, replace the faulty board.
5. If the alarm persists, collect alarm, log, and configuration information and contact technical support engineers.
6. End.