DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.5 hwBoardInvalid-132671

Trap Buffer Description

The board totally failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=132671, Reason=The EPLD2 logic of the board failed.)

The overall function of the board does not take effect.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwBoardInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.2.5

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x0813002e

Alarm Name

hwBoardInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.6 hwBoardInvalidResume-132671

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the entity such as a chassis.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

  • 1: mpu(1)
  • 2: lpu(2)
  • 3: sfu(3)
  • 4: pic(4)
  • 5: cfcard(5)
  • 6: ofc(6)
  • 7: npu(7)

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

Services on the board will be affected or even interrupted. This problem must be resolved immediately.

Possible Causes

The EPLD2 logic of the board failed.

Procedure

1. Go to Step 2 if the faulty board is not the main control board.

2. If the faulty board is registered, run the EPlD2 upgrade command in the user view: upgrade mpu/lpu/sfu slotid startup firmware. Then go to Step 4.

3. If the faulty board is not registered, power off and then power on the faulty board.

4. If the faulty board cannot be registered or the fault persists after the board is registered, replace the faulty board.

5. If the alarm persists, collect alarm, log, and configuration information and contact technical support engineers.

6. End.