DEVM_1.3.6.1.4.1.2011.5.25.219.2.30.1 hwInsSpaceLackAlarm-147968

Trap Buffer Description

Instruction space not enough.(EntityPhysicalIndex=[EntityPhysicalIndex], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[147968], Reason=The instruction space required is too more.)

There is insufficient space for the forwarding instruction to generate an alarm.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwInsSpaceLackAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.30.1

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08012234

Alarm Name

hwInsSpaceLackAlarm

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.30.2 hwInsSpaceLackResume-147968

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalName

Indicates the name of the physical entity.

EntityTrapFaultID

Indicates the error code.

Reason

Indicates the reason.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

Impact on the System

The current configuration cannot be fully take effect.

Possible Causes

The instruction space required is too more.

Procedure

1.Delete some of the configuration or replace the board with larger instruction space. Then check whether the alarm is cleared.

  • If so, go to Step 3.
  • If not, go to Step 2.

2.Collect the trap information, log information, and configuration of the router, and contact technical support personnel.

3.End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.