DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.13 hwOpticalTunableNotMatch-137984

Trap Buffer Description

Configuration collision occurred between wavelength setting and untunable optical module. (EntityPhysicalIndex=[hwEntityPhysicalIndex], EntPhysicalIndex=[entPhysicalIndex], EntPhysicalName=[entPhysicalName], EntityTrapFaultID=[hwEntityTrapFaultID])

Configuration collision occurred between wavelength setting and untunable optical module.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwOpticalTunableNotMatch

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.4.13

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08012091

Alarm Name

hwOpticalTunableNotMatch

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.14 hwOpticalTunableNotMatchResume-137984

Trap Buffer Parameters

Parameter Description

hwEntityPhysicalIndex

Index of physical port.

entPhysicalIndex

Index of physical port.

entPhysicalName

Name of the physical entity.

hwEntityTrapFaultID

Error code.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

Impact on the System

Configuration collision occurred between wavelength setting and untunable optical module.

Possible Causes

A wavelength-tunable optical module is configured, whereas a wavelength-fixed one is installed.

Procedure

1. Run the display this command in a specified interface view and check whether the wavelength is configured.

  • If the wavelength is configured, go to Step 2.
  • If the wavelength is not configured, go to Step 4.

2. Run the display this interface command in a specified interface view and check whether the center wavelength of the optical module is tunable.

  • If the center wavelength of the optical module is tunable, go to Step 3.
  • If the center wavelength of the optical module is not tunable, go to Step 4.

3. Replace the optical module and re-install the wavelength-tunable optical module. Alternatively, run the undo wavelength command to delete the center wavelength. Check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm persists, go to Step 4.

4. Collect alarm information, log information and configuration information, and then contact technical support personnel.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >