DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.5 hwOpticalInvalid-136198

Trap Buffer Description

The optical module failed completely. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136198, ReasonDescription=The voltage of the optical module was too low.)

The optical module failed completely.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwOpticalInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.4.5

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08130059

Alarm Name

hwOpticalInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.6 hwOpticalInvalidResume-136198

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Index of the physical entity.

EntPhysicalIndex

Index of the physical entity.

EntityTrapFaultID

Error code.

EntPhysicalName

Name of the physical entity.

ReasonDescription

Indicates the description of the possible cause.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

Impact on the System

Services may be interrupted.

Possible Causes

The voltage of the optical module was too low.

Procedure

1. Run the display alarm all command to check whether hwPowerInvalid is generated on the interface.

  • If so, go to Step 2.
  • If not, go to Step 3.

2. Clear the power alarm, and then check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 8.
  • If the alarm persists, go to Step 3.

3. Check the current information of the board where the optical module is located, and check whether the current alarm information exists on the NMS.

  • If so, go to Step 4.
  • If not, go to Step 5.

4. Handle the current alarm, and then check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 8.
  • If the alarm persists, go to Step 5.

5. Replace the optical module, and then check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 8.
  • If the alarm persists, go to Step 6.

6. Replace the board on which the optical module is installed, and then check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 8.
  • If the alarm persists, go to Step 7.

7. Collect trap, log, and configuration information, and contact technical support.

8. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >