The optical module failed completely. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136201, ReasonDescription=The temperature of the optical module was too high.)
The optical module failed completely.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwOpticalInvalid |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.4.5 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x08130059 |
Alarm Name |
hwOpticalInvalid |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.6 hwOpticalInvalidResume-136201 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
Index of the physical entity. |
EntPhysicalIndex |
Index of the physical entity. |
EntityTrapFaultID |
Error code. |
EntPhysicalName |
Name of the physical entity. |
ReasonDescription |
Indicates the description of the possible cause. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1. Run the display alarm all command to check whether hwPowerInvalid is generated on the interface.
2. Clear the power alarm, and then check whether the alarm is cleared.
3. Check the current information of the board where the optical module is located, and check whether the current alarm information exists on the NMS.
4. Handle the current alarm, and then check whether the alarm is cleared.
5. Replace the optical module, and then check whether the alarm is cleared.
6. Replace the board on which the optical module is installed, and then check whether the alarm is cleared.
7. Collect trap, log, and configuration information, and contact technical support.
8. End.