DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.5 hwOpticalInvalid-136225

Trap Buffer Description

The optical module failed completely. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136225, ReasonDescription=The receiving total power of the optical module is too high.)

The optical module failed completely.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwOpticalInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.4.5

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08130059

Alarm Name

hwOpticalInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.6 hwOpticalInvalidResume-136225

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Index of the physical entity.

EntPhysicalIndex

Index of the physical entity.

EntityTrapFaultID

Error code.

EntPhysicalName

Name of the physical entity.

ReasonDescription

Indicates the description of the possible cause.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

Impact on the System

Services on the optical module will be affected. For example, error codes or packets may occur, the optical module may be damaged, or services are even interrupted. Thus, a speedy solution is required.

Possible Causes

The receiving total power of the optical module is too high.

Procedure

1. Run the display interface command in the user view to check whether the input optical power (Rx Power) on the current interface is in the normal range. If the Rx power is in the normal range, go to Step 4.

  • If the remote interface is physically Up and no alarm indicating low output optical power is generated on the remote interface, go to Step 5.
  • If the remote interface is physically Down and an alarm indicating interface Down is generated on the remote interface, rectify the fault on the remote interface.

2. Check whether the fiber is faulty. If so, replace the fiber.

3. Replace the optical module on the local interface. If the alarm persists after the optical module is replaced, go to Step 4.

4. Collect trap, log, and configuration information, and contact technical support.

5. End.