The optical module failed completely. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136225, ReasonDescription=The receiving total power of the optical module is too high.)
The optical module failed completely.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwOpticalInvalid |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.4.5 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x08130059 |
Alarm Name |
hwOpticalInvalid |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.6 hwOpticalInvalidResume-136225 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
Index of the physical entity. |
EntPhysicalIndex |
Index of the physical entity. |
EntityTrapFaultID |
Error code. |
EntPhysicalName |
Name of the physical entity. |
ReasonDescription |
Indicates the description of the possible cause. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1. Run the display interface command in the user view to check whether the input optical power (Rx Power) on the current interface is in the normal range. If the Rx power is in the normal range, go to Step 4.
2. Check whether the fiber is faulty. If so, replace the fiber.
3. Replace the optical module on the local interface. If the alarm persists after the optical module is replaced, go to Step 4.
4. Collect trap, log, and configuration information, and contact technical support.
5. End.