A power module experienced a partial failure.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136707, Reason=The power module failed.)
The power supply experienced a partial failure, which may be caused by a component failure.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwPowerFail |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.5.3 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x0813001d |
Alarm Name |
hwPowerFail |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.4 hwPowerFailResume-136707 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalIndex |
The index for this entry. |
EntityTrapFaultID |
To describe the fault id of trap. |
EntPhysicalName |
The textual name of the physical entity. |
Reason |
Reason. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2 |
hwEntityOperStatus |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.13 |
hwEntityTrapReasonDescr |
- |
1. Run the display device slot-id command in the user view to view information about the faulty power supply module. Check whether all components are in PRESENT state and all the Status items are normal.
2. Replace the faulty components or the power supply module.
3. If the alarm persists, collect trap, log, and configuration information, and contact technical support.
4. End.