DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.5 hwPowerInvalid-136974

Trap Buffer Description

A power module experienced a complete failure.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136974, Reason=The device power is Insufficient.)

Power invalid.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwPowerInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.5.5

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x0813001b

Alarm Name

hwPowerInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.6 hwPowerInvalidResume-136974

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

The index for this entry.

EntPhysicalIndex

The index for this entry.

EntityTrapFaultID

To describe the fault id of trap.

EntPhysicalName

The textual name of the physical entity.

Reason

Reason.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

Impact on the System

This failure will result in insufficient power supply for a router, thus powering off or resetting a board and indirect impacting services. Thus, a speedy solution is required.

Possible Causes

The device power is Insufficient.

Procedure

1. Check whether the voltage value is able to support the device running in the normal status.

2. Check whether the backup power module exists.

3. Check whether the power module is damaged.

Copyright © Huawei Technologies Co., Ltd.