DEVM_1.3.6.1.4.1.2011.5.25.219.2.6.1 hwFanRemove-137216

Trap Buffer Description

A fan module was removed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=137216, Reason=A fan module was removed.)

A fan module was removed.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwFanRemove

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.6.1

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08130019

Alarm Name

hwFanRemove

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.6.2 hwFanInsert-137216

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

The index for this entry.

EntPhysicalIndex

The index for this entry.

EntityTrapFaultID

To describe the fault id of trap.

EntPhysicalName

The textual name of the physical entity.

Reason

Reason.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

Impact on the System

The temperature will be higher, the board maybe work unstable.

Possible Causes

A fan module was removed.

Procedure

1.Check whether the fan module is properly installed in the slot.

  • If so, replace the fan module.
  • If not, install the fan module properly.

2.If the alarm still exists, collect trap, log, and configuration information, and contact technical support personnel.

3.End.