The fan partially failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=137472, Reason=The fan module was in the abnormal state.)
The fan module experienced a partial failure.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Warning |
Mnemonic Code |
hwFanFail(entityTrap) |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.6.3 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x08130036 |
Alarm Name |
hwFanFail(entityTrap) |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.6.4 hwFanFail(entityTrap)Resume-137472 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalName |
The textual name of the physical entity. |
EntityTrapFaultID |
To describe the fault id of trap. |
Reason |
Reason. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.Check whether the fan module is properly installed in the slot.
2.If so, replace the fan module;otherwise, install the fan module properly.
3.Collect alarm information, log information and configuration information, and then contact Huawei technical support personnel.
4.End.