DEVM_1.3.6.1.4.1.2011.5.25.219.2.6.5 hwFanInvalid-139272

Trap Buffer Description

The fan module failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=139272, Reason=The first 48V power supply of the fan module is faulty.)

The fan function is disabled.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwFanInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.6.5

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08130017

Alarm Name

hwFanInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.6.6 hwFanInvalidResume-139272

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

The index for this entry.

EntPhysicalIndex

The index for this entry.

EntityTrapFaultID

To describe the fault id of trap.

EntPhysicalName

The textual name of the physical entity.

Reason

Reason.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

Impact on the System

The device heat dissipation will be affected. The services will not be affected in a short time but will be affected if the alarm persists for a long time.

Possible Causes

The first 48V power supply of the fan module is faulty.

Procedure

1. Remove and re-install the problem fan module. Then, check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 5.
  • If the alarm persists, go to Step 2.

2. Swap the slot of the problem fault module with that of a normal fan module. Then, check whether the alarm is cleared.

  • If the problem fan module still reports the alarm in the new slot, go to Step 3.
  • If the slot housing the problem fan module reports the alarm, go to Step 4.

3. Replace the problem fan module. Then, check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 5.
  • If the alarm persists, go to Step 4.

4. Contact technical support personnel and provide them with collected logs.

5. End.