The fan module was unavailable.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])
The fan module was unavailable.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Warning |
Mnemonic Code |
hwFanUnusable |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.6.7 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x08130046 |
Alarm Name |
hwFanUnusable |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
Parameter | Description |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalName |
The textual name of the physical entity. |
EntityTrapFaultID |
To describe the fault id of trap. |
Reason |
Reason. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1. Replace the fan module, and then check whether the alarm is cleared. If the alarm persists, collect alarm information, log information and configuration information, and then contact technical support personnel.
2. End.