Symbol error alarm.(hwIfMonitorIndex=[hwIfMonitorIndex], hwIfMonitorSymbolErrorStatistics=[hwIfMonitorSymbolErrorStatistics], hwIfMonitorSymbolErrorThreshold=[hwIfMonitorSymbolErrorThreshold], hwIfMonitorSymbolErrorInterval=[hwIfMonitorSymbolErrorInterval], hwIfMonitorName=[hwIfMonitorName])
Symbol error alarm.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwIfMonitorSymbolErrorRising |
Trap OID |
1.3.6.1.4.1.2011.5.25.41.4.18 |
MIB |
HUAWEI-IF-EXT-MIB |
Alarm ID |
0x0813213d |
Alarm Name |
hwIfMonitorSymbolErrorRising |
Alarm Type |
processingErrorAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.41.4.19 hwIfMonitorSymbolErrorResume |
Parameter | Description |
---|---|
hwIfMonitorIndex |
Index of physical port. |
hwIfMonitorSymbolErrorStatistics |
Symbol error statistics value. |
hwIfMonitorSymbolErrorThreshold |
Symbol error alarm threshold. |
hwIfMonitorSymbolErrorInterval |
Symbol error alarm interval time(unit is second),default value is 10s. |
hwIfMonitorName |
Name of physical port. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.41.1.7.1.1.26 |
hwIfMonitorSymbolErrorStatistics |
hwIfMonitorIndex |
1.3.6.1.4.1.2011.5.25.41.1.7.1.1.27 |
hwIfMonitorSymbolErrorThreshold |
hwIfMonitorIndex |
1.3.6.1.4.1.2011.5.25.41.1.7.1.1.28 |
hwIfMonitorSymbolErrorInterval |
hwIfMonitorIndex |
1.3.6.1.4.1.2011.5.25.41.1.7.1.1.19 |
hwIfMonitorName |
hwIfMonitorIndex |
1.Replace the optical module and then check whether the fault is rectified.
2.Replace the optical fiber, and then check whether the fault is rectified.
3.Collect alarm information, log information and configuration information, and then contact technical support personnel.