DEVM_1.3.6.1.4.1.2011.5.25.41.4.2 hwIfMonitorCrcErrorResume

Trap Buffer Description

The CRC error alarm resume. (hwIfMonitorIndex=[hwIfMonitorIndex], hwIfMonitorCrcErrorStatistics=[hwIfMonitorCrcErrorStatistics], hwIfMonitorCrcErrorThreshold=[hwIfMonitorCrcErrorThreshold], hwIfMonitorCrcErrorInterval=[hwIfMonitorCrcErrorInterval], hwIfMonitorName=[hwIfMonitorName])

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwIfMonitorCrcErrorRising

Trap OID

1.3.6.1.4.1.2011.5.25.41.4.2

MIB

HUAWEI-IF-EXT-MIB

Alarm ID

0x081300bc

Alarm Name

hwIfMonitorCrcErrorRising

Alarm Type

processingErrorAlarm

Raise or Clear

Clear

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.41.4.1 hwIfMonitorCrcErrorRising

Trap Buffer Parameters

Parameter Description

hwIfMonitorIndex

Index of physical port.

hwIfMonitorCrcErrorStatistics

CRC error statistics value.

hwIfMonitorCrcErrorThreshold

CRC error alarm threshold.

hwIfMonitorCrcErrorInterval

CRC error alarm interval time(unit is second),default value is 10s and 0 is an invalid value.

hwIfMonitorName

Name of physical port.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.2

hwIfMonitorCrcErrorStatistics

hwIfMonitorIndex

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.3

hwIfMonitorCrcErrorThreshold

hwIfMonitorIndex

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.4

hwIfMonitorCrcErrorInterval

hwIfMonitorIndex

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.19

hwIfMonitorName

hwIfMonitorIndex

Impact on the System

The system will not be affected.

Possible Causes

The trap generated because the number of packets dropped due to CRC errors exceeded the threshold was cleared.

Procedure

This trap message is informational only, and no action is required.