Interface input flow bandwidth usage exceeded the trap threshold. (Interface=[IfIndex], BandWidthUsage=[hwSubIfInputRatePercentage], TrapThreshold=[hwSubIfInputRateThreshold], InterfaceName=[InterfaceName])
Interface input flow bandwidth usage exceeded the trap threshold.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Warning |
Mnemonic Code |
subIfInputRateRising |
Trap OID |
1.3.6.1.4.1.2011.5.25.41.4.5 |
MIB |
HUAWEI-IF-EXT-MIB |
Alarm ID |
0x081300ae |
Alarm Name |
hwIfMonitorInputRateRising |
Alarm Type |
processingErrorAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.41.4.6 hwIfMonitorInputRateResume |
Parameter | Description |
---|---|
IfIndex |
Interface index . |
hwSubIfInputRatePercentage |
Input flow bandwidth usage. |
hwSubIfInputRateThreshold |
Trap threshold. |
InterfaceName |
Interface name. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.41.1.7.1.1.8 |
hwIfMonitorInputRate |
hwIfMonitorIndex |
1.3.6.1.4.1.2011.5.25.41.1.7.1.1.9 |
hwIfMonitorInputRateThreshold |
hwIfMonitorIndex |
1.3.6.1.4.1.2011.5.25.41.1.7.1.1.19 |
hwIfMonitorName |
hwIfMonitorIndex |
1.Run the display this interface command in the interface view to check whether the traffic volume threshold is proper for the actual service conditions.
2.Run the trap-threshold input-rate threshold_value command in the interface view to set a proper alarm threshold. Then, check whether the alarm is cleared.
3.Collect the trap, log, and configuration information, and then contact technical support personnel.
4.End.