DRIVER_1.3.6.1.4.1.2011.5.25.157.2.317 hwFlexEGrpSpeedModeMismatch

Trap Buffer Description

The speed modes of the FlexE physical interfaces in the FlexEGroup mismatch alarm.(GroupIndex=[hwFlexEGroupIndex],GroupName=[hwFlexEGroupName])

The speed modes of the FlexE physical interfaces in the FlexEGroup mismatch alarm.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwFlexEGrpSpeedModeMismatch

Trap OID

1.3.6.1.4.1.2011.5.25.157.2.317

MIB

HUAWEI-PORT-MIB

Alarm ID

0x080122a4

Alarm Name

hwFlexEGrpSpeedModeMismatch

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

DRIVER_1.3.6.1.4.1.2011.5.25.157.2.318 hwFlexEGrpSpeedModeMismatchResume

Trap Buffer Parameters

Parameter Description

hwFlexEGroupIndex

Index of FlexE group.

hwFlexEGroupName

Name of FlexE Group.This parameter specifies the slot and card informations and group index which the group belongs.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.157.1.30.5

hwFlexEGroupIndex

-

1.3.6.1.4.1.2011.5.25.157.1.30.6

hwFlexEGroupName

-

Impact on the System

Services on the interface are affected.

Possible Causes

The rates of the physical interfaces bound to the FlexE group are different.

Procedure

1. Check whether the bandwidths of the FlexE physical interfaces in the FlexE group are the same.

  • If so, go to Step 5.
  • If not, go to Step 2.

2. Check whether the FlexE physical interfaces in the group support forcible switchover or auto-sensing.

  • If the interfaces support forcible switchover, auto-sensing, or both, go to Step 3.
  • If the interfaces support neither forcible switchover nor auto-sensing, go to Step 4.

3. Run the port-speed command or insert an optical module to ensure that the bandwidths of the FlexE physical interfaces in the group are the same. Then check whether the alarm is cleared.

  • If so, go to Step 6.
  • If not, go to Step 4.

4. Re-select physical interfaces and bind them in the group to ensure that the bandwidths of the physical interfaces are the same. Then, check whether the alarm is cleared.

  • If so, go to Step 6.
  • If not, go to Step 5.

5. Collect alarm, log, and configuration information, and contact technical support personnel.

6. End.