The outbound RTP-SER of the channel exceeds the threshold. (ChannelName=[hwEmdiChannelName], ChannelSourceAddress=[hwEmdiChannelSourceAddress], ChannelGroupAddress=[hwEmdiChannelGroupAddress], RtpSerThreshold=[hwEmdiRtpSerThreshold], RtpSer=[hwEmdiRtpSerValue], Slot=[hwEmdiChannelSlot], Interface=[hwEmdiChannelInterface])
The outbound RTP-SER of the channel exceeds the threshold.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Warning |
Mnemonic Code |
hwEmdiOutRtpSerOverThreshold |
Trap OID |
1.3.6.1.4.1.2011.5.25.349.2.1.11 |
MIB |
HUAWEI-QOE-MIB |
Alarm ID |
0x00F102ea |
Alarm Name |
hwEmdiOutRtpSerOverThreshold |
Alarm Type |
qualityOfServiceAlarm |
Raise or Clear |
Raise |
Match trap |
EMDI_1.3.6.1.4.1.2011.5.25.349.2.1.12 hwEmdiOutRtpSerOverThresholdResume |
Parameter | Description |
---|---|
hwEmdiChannelName |
Channel name. |
hwEmdiChannelSourceAddress |
Channel source address. |
hwEmdiChannelGroupAddress |
Channel group address. |
hwEmdiRtpSerThreshold |
Current RTP-SER threshold of a channel. |
hwEmdiRtpSerValue |
Current RTP-SER value. |
hwEmdiChannelSlot |
Slot ID. |
hwEmdiChannelInterface |
Interface Name. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.349.1.1.1.1 |
hwEmdiChannelName |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.2 |
hwEmdiChannelSourceAddress |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.3 |
hwEmdiChannelGroupAddress |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.6 |
hwEmdiRtpSerThreshold |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.7 |
hwEmdiRtpSerValue |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.8 |
hwEmdiChannelSlot |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.9 |
hwEmdiChannelInterface |
- |
1.According to the eMDI statistical information to confirm the fault equipment. (eMDI does not differentiate upstream and downstream traffic. eMDI needs to globally analyze fault points on the entire network based on information about each detection point.)
2.Replace optical modules or optical fibers of faulty equipment. Then check whether the trap is cleared.
3.Collect trap, log, and configuration information, and then contact technical support personnel.
4.End.