EMDI_1.3.6.1.4.1.2011.5.25.349.2.1.13 hwEmdiBierRtpLrOverThreshold

Trap Buffer Description

Channel packet loss rate exceeds the threshold. (ChannelSourceAddress=[hwEmdiChannelSourceAddress], ChannelGroupAddress=[hwEmdiChannelGroupAddress], VpnLabel=[hwEmdiVpnLabel], BfirId=[hwEmdiBfirId], SubDomain=[hwEmdiSubDomain], Bsl=[hwEmdiBsl], SI=[hwEmdiSi], RtpLrThreshold=[hwEmdiRtpLrThreshold], RtpLr=[hwEmdiRtpLrValue])

Channel RTP-LR exceeds the threshold.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwEmdiBierRtpLrOverThreshold

Trap OID

1.3.6.1.4.1.2011.5.25.349.2.1.13

MIB

HUAWEI-QOE-MIB

Alarm ID

0x00f10448

Alarm Name

hwEmdiBierRtpLrOverThreshold

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

EMDI_1.3.6.1.4.1.2011.5.25.349.2.1.14 hwEmdiBierRtpLrOverThresholdResume

Trap Buffer Parameters

Parameter Description

hwEmdiChannelSourceAddress

Channel source address.

hwEmdiChannelGroupAddress

Channel group address.

hwEmdiVpnLabel

VPN label.

hwEmdiBfirId

Bit forwarding ingress router id.

hwEmdiSubDomain

Sub domain.

hwEmdiBsl

BitString length.

hwEmdiSi

Set identifier.

hwEmdiRtpLrThreshold

Current packet loss rate threshold of a channel.

hwEmdiRtpLrValue

Current packet loss rate value.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.349.1.1.1.2

hwEmdiChannelSourceAddress

-

1.3.6.1.4.1.2011.5.25.349.1.1.1.3

hwEmdiChannelGroupAddress

-

1.3.6.1.4.1.2011.5.25.349.1.1.1.10

hwEmdiVpnLabel

-

1.3.6.1.4.1.2011.5.25.349.1.1.1.11

hwEmdiBfirId

-

1.3.6.1.4.1.2011.5.25.349.1.1.1.12

hwEmdiSubDomain

-

1.3.6.1.4.1.2011.5.25.349.1.1.1.13

hwEmdiBsl

-

1.3.6.1.4.1.2011.5.25.349.1.1.1.14

hwEmdiSi

-

1.3.6.1.4.1.2011.5.25.349.1.1.1.4

hwEmdiRtpLrThreshold

-

1.3.6.1.4.1.2011.5.25.349.1.1.1.5

hwEmdiRtpLrValue

-

Impact on the System

The quality of the specified multicast channel is poor.

Possible Causes

The rate of disordered bier channel packets was too large.

Procedure

1.According to the Bier eMDI statistical information to confirm the fault equipment. (Bier eMDI does not differentiate upstream and downstream traffic. Bier eMDI needs to globally analyze fault points on the entire network based on information about each detection point.)

2.Replace optical modules or optical fibers of faulty equipment. Then check whether the trap is cleared.

  • If the trap is cleared, go to Step 4.
  • If the trap persists, go to Step 3.

3.Collect trap, log, and configuration information, and then contact technical support personnel.

4.End.