Channel packet loss rate exceeds the threshold. (ChannelSourceAddress=[hwEmdiChannelSourceAddress], ChannelGroupAddress=[hwEmdiChannelGroupAddress], VpnLabel=[hwEmdiVpnLabel], BfirId=[hwEmdiBfirId], SubDomain=[hwEmdiSubDomain], Bsl=[hwEmdiBsl], SI=[hwEmdiSi], RtpLrThreshold=[hwEmdiRtpLrThreshold], RtpLr=[hwEmdiRtpLrValue])
Channel RTP-LR exceeds the threshold.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Warning |
Mnemonic Code |
hwEmdiBierRtpLrOverThreshold |
Trap OID |
1.3.6.1.4.1.2011.5.25.349.2.1.13 |
MIB |
HUAWEI-QOE-MIB |
Alarm ID |
0x00f10448 |
Alarm Name |
hwEmdiBierRtpLrOverThreshold |
Alarm Type |
qualityOfServiceAlarm |
Raise or Clear |
Raise |
Match trap |
EMDI_1.3.6.1.4.1.2011.5.25.349.2.1.14 hwEmdiBierRtpLrOverThresholdResume |
Parameter | Description |
---|---|
hwEmdiChannelSourceAddress |
Channel source address. |
hwEmdiChannelGroupAddress |
Channel group address. |
hwEmdiVpnLabel |
VPN label. |
hwEmdiBfirId |
Bit forwarding ingress router id. |
hwEmdiSubDomain |
Sub domain. |
hwEmdiBsl |
BitString length. |
hwEmdiSi |
Set identifier. |
hwEmdiRtpLrThreshold |
Current packet loss rate threshold of a channel. |
hwEmdiRtpLrValue |
Current packet loss rate value. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.349.1.1.1.2 |
hwEmdiChannelSourceAddress |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.3 |
hwEmdiChannelGroupAddress |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.10 |
hwEmdiVpnLabel |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.11 |
hwEmdiBfirId |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.12 |
hwEmdiSubDomain |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.13 |
hwEmdiBsl |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.14 |
hwEmdiSi |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.4 |
hwEmdiRtpLrThreshold |
- |
1.3.6.1.4.1.2011.5.25.349.1.1.1.5 |
hwEmdiRtpLrValue |
- |
1.According to the Bier eMDI statistical information to confirm the fault equipment. (Bier eMDI does not differentiate upstream and downstream traffic. Bier eMDI needs to globally analyze fault points on the entire network based on information about each detection point.)
2.Replace optical modules or optical fibers of faulty equipment. Then check whether the trap is cleared.
3.Collect trap, log, and configuration information, and then contact technical support personnel.
4.End.