EMDI_1.3.6.1.4.1.2011.5.25.349.2.1.3 hwEmdiRtpSerOverThreshold

Trap Buffer Description

Channel RTP-SER exceeds the threshold. (ChannelName=[hwEmdiChannelName], ChannelSourceAddress=[hwEmdiChannelSourceAddress], ChannelGroupAddress=[hwEmdiChannelGroupAddress], RtpSerThreshold=[hwEmdiRtpSerThreshold], RtpSer=[hwEmdiRtpSerValue])

The channel RTP-SER exceeded the threshold.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwEmdiRtpSerOverThreshold

Trap OID

1.3.6.1.4.1.2011.5.25.349.2.1.3

MIB

HUAWEI-QOE-MIB

Alarm ID

0x00F10242

Alarm Name

hwEmdiRtpSerOverThreshold

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

EMDI_1.3.6.1.4.1.2011.5.25.349.2.1.4 hwEmdiRtpSerOverThresholdResume

Trap Buffer Parameters

Parameter Description

hwEmdiChannelName

Channel name.

hwEmdiChannelSourceAddress

Channel source address.

hwEmdiChannelGroupAddress

Channel group address.

hwEmdiRtpSerThreshold

Current RTP-SER threshold of a channel.

hwEmdiRtpSerValue

Current RTP-SER value.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.349.1.1.1.1

hwEmdiChannelName

-

1.3.6.1.4.1.2011.5.25.349.1.1.1.2

hwEmdiChannelSourceAddress

-

1.3.6.1.4.1.2011.5.25.349.1.1.1.3

hwEmdiChannelGroupAddress

-

1.3.6.1.4.1.2011.5.25.349.1.1.1.6

hwEmdiRtpSerThreshold

-

1.3.6.1.4.1.2011.5.25.349.1.1.1.7

hwEmdiRtpSerValue

-

Impact on the System

The quality of the specified multicast channel is poor.

Possible Causes

The rate of disordered channel packets was too large.

Procedure

1.According to the eMDI statistical information to confirm the fault equipment. (eMDI does not differentiate upstream and downstream traffic. eMDI needs to globally analyze fault points on the entire network based on information about each detection point.)

2.Replace optical modules or optical fibers of faulty equipment. Then check whether the trap is cleared.

  • If the trap is cleared, go to Step 4.
  • If the trap persists, go to Step 3.

3.Collect trap, log, and configuration information, and then contact technical support personnel.

4.End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.