EOAM-1AG_1.3.6.1.4.1.2011.5.25.136.1.6.34 hwDot1agCfmMismerge

Trap Buffer Description

MEP received a CCM with unexpected MEG ID. (MdIndex=[MdIndex], MaIndex=[MaIndex], MdName=[MdName], MaName=[MaName], MepId=[MepId])

An MD or MA name carried in a CCM sent by the RMEP was different from that specified on the MEP.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

MISMERGE

Trap OID

1.3.6.1.4.1.2011.5.25.136.1.6.34

MIB

HUAWEI-ETHOAM-MIB

Alarm ID

0x09ac0002

Alarm Name

MISMERGE

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

EOAM-1AG_1.3.6.1.4.1.2011.5.25.136.1.6.35 hwDot1agCfmMismergeCleared

Trap Buffer Parameters

Parameter Description

MdName

Name of an MD

MaName

Name of an MA

MepId

ID of a MEP

ifName

Name of interface

Vlan

Vlan ID

Direction

Direction

Level

Level of MD

MdIndex

Index of an MD table

MaIndex

Index of an MA table

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.136.1.1.3.2.1.3

hwDot1agCfmMdName

hwDot1agCfmMdIndex

1.3.6.1.4.1.2011.5.25.136.1.1.4.2.1.2

hwDot1agCfmMaName

hwDot1agCfmMdIndex

hwDot1agCfmMaIndex

1.3.6.1.4.1.2011.5.25.136.1.1.5.1.1.1

hwDot1agCfmMepIdentifier

hwDot1agCfmMdIndex

hwDot1agCfmMaIndex

hwDot1agCfmMepIdentifier

Impact on the System

CFM will fail.

Possible Causes

An MD or MA name carried in a CCM sent by the RMEP was different from that specified on the MEP when the MEP and RMEP had the same MD level and service type in a MEG.

Procedure

1. Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command to view the value of the MD Name field on the MEP and RMEP that have the same service type and MD level. Check whether the MD names are the same.

  • If they are the same, go to Step 2.
  • If they are different, go to Step 3.

2. Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command to view the value of the MA Name field on the MEP and RMEP that have the same service type, MD level, and MD name. Check whether the MA names are the same.

  • If they are the same, go to Step 5.
  • If they are different, go to Step 4.

3. Perform the following steps on the MEP:

  • a. Run the undo cfm md name md-name command to delete existing MD configurations.
  • b. Run the cfm md md-name level leve command to reconfigure an MD the same as that on the RMEP.
  • c. Run the display alarm active command to view the trap. Check whether the trap is cleared. If the trap persists, go to Step 5.

4. Perform the following steps on the MEP:

  • a. Run the undo ma ma-name command to delete existing MA configurations.
  • b. Run the ma ma-name command to reconfigure an MA the same as that on the RMEP.
  • c. Run the display alarm active command to view the trap. Check whether the trap is cleared. If the trap persists, go to Step 5.

5. Collect alarm information and configuration information, and then contact technical support personnel.