EOAM-1AG_1.3.6.1.4.1.2011.5.25.136.1.6.40 hwDot1agCfmUnexpectedMAC

Trap Buffer Description

MEP received a CCM with unexpected MAC address. (MdIndex=[MdIndex], MaIndex=[MaIndex], MdName=[MdName], MaName=[MaName], MepId=[MepId], RmepId=[RmepId])

The source MAC address carried in a CCM sent by the RMEP was different from the RMEP's MAC address specified on the MEP.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

UNEXPECTEDMAC

Trap OID

1.3.6.1.4.1.2011.5.25.136.1.6.40

MIB

HUAWEI-ETHOAM-MIB

Alarm ID

0x09ac0008

Alarm Name

UNEXPECTEDMAC

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

EOAM-1AG_1.3.6.1.4.1.2011.5.25.136.1.6.41 hwDot1agCfmUnexpectedMACCleared

Trap Buffer Parameters

Parameter Description

MdIndex

Index of an MD table

MaIndex

Index of an MA table

MdName

Name of an MD

MaName

Name of an MA

MepId

ID of a MEP

RmepId

ID of an RMEP

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.136.1.1.3.2.1.3

hwDot1agCfmMdName

hwDot1agCfmMdIndex

1.3.6.1.4.1.2011.5.25.136.1.1.4.2.1.2

hwDot1agCfmMaName

hwDot1agCfmMdIndex

hwDot1agCfmMaIndex

1.3.6.1.4.1.2011.5.25.136.1.1.5.1.1.1

hwDot1agCfmMepIdentifier

hwDot1agCfmMdIndex

hwDot1agCfmMaIndex

hwDot1agCfmMepIdentifier

1.3.6.1.4.1.2011.5.25.136.1.1.6.1.1.1

hwDot1agCfmRMepIdentifier

hwDot1agCfmMdIndex

hwDot1agCfmMaIndex

hwDot1agCfmRMepIdentifier

Impact on the System

CFM will fail.

Possible Causes

The source MAC address carried in a CCM sent by the RMEP was different from the RMEP's MAC address specified on the MEP under the following conditions:

  • The MEP and RMEP had the same MD level.
  • The MEP and RMEP had the same MA ID.
  • The MEP ID carried in the received CCMs was listed in the RMEP list on the MEP.
  • The MEP was enabled to receive CCMs.
  • The MEP and RMEP had the same interval at which CCMs were sent.

Procedure

1. Run the cfm md md-name command on the MEP to enter the MD view. Run the display this command on the MEP to view the RMEP's MAC address. Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command on the RMEP to view the value of the MAC field. Check whether the value of the MAC field on the RMEP is the same as the RMEP's MAC address on the MEP.

  • a. Run the cfm md md-name command on the MEP to enter the MD view.
  • b. Run the display this command on the MEP to view the RMEP's MAC address.
  • c. Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command on the RMEP to view the value of the MAC field.
  • d. Check whether the value of the MAC field on the RMEP is the same as the RMEP's MAC address on the MEP.
  • If they are the same, go to Step 3.
  • If they are different, go to Step 2.

2. Perform the following steps on the MEP:

  • a. Run the undo remote-mep mep-id mep-id command to delete the existing RMEP configuration.
  • b. Run the remote-mep mep-id mep-id mac mac-address command to specify the correct MAC address of the RMEP.
  • c. Run the display alarm active command to view the trap. Check whether the trap is cleared. If the trap persists, go to Step 3.

3. Collect alarm information and configuration information, and then contact technical support personnel.