MEP received a CCM with unexpected MAC address. (MdIndex=[MdIndex], MaIndex=[MaIndex], MdName=[MdName], MaName=[MaName], MepId=[MepId], RmepId=[RmepId])
The source MAC address carried in a CCM sent by the RMEP was different from the RMEP's MAC address specified on the MEP.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Error |
Mnemonic Code |
UNEXPECTEDMAC |
Trap OID |
1.3.6.1.4.1.2011.5.25.136.1.6.40 |
MIB |
HUAWEI-ETHOAM-MIB |
Alarm ID |
0x09ac0008 |
Alarm Name |
UNEXPECTEDMAC |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
EOAM-1AG_1.3.6.1.4.1.2011.5.25.136.1.6.41 hwDot1agCfmUnexpectedMACCleared |
Parameter | Description |
---|---|
MdIndex |
Index of an MD table |
MaIndex |
Index of an MA table |
MdName |
Name of an MD |
MaName |
Name of an MA |
MepId |
ID of a MEP |
RmepId |
ID of an RMEP |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.136.1.1.3.2.1.3 |
hwDot1agCfmMdName |
hwDot1agCfmMdIndex |
1.3.6.1.4.1.2011.5.25.136.1.1.4.2.1.2 |
hwDot1agCfmMaName |
hwDot1agCfmMdIndex hwDot1agCfmMaIndex |
1.3.6.1.4.1.2011.5.25.136.1.1.5.1.1.1 |
hwDot1agCfmMepIdentifier |
hwDot1agCfmMdIndex hwDot1agCfmMaIndex hwDot1agCfmMepIdentifier |
1.3.6.1.4.1.2011.5.25.136.1.1.6.1.1.1 |
hwDot1agCfmRMepIdentifier |
hwDot1agCfmMdIndex hwDot1agCfmMaIndex hwDot1agCfmRMepIdentifier |
The source MAC address carried in a CCM sent by the RMEP was different from the RMEP's MAC address specified on the MEP under the following conditions:
1. Run the cfm md md-name command on the MEP to enter the MD view. Run the display this command on the MEP to view the RMEP's MAC address. Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command on the RMEP to view the value of the MAC field. Check whether the value of the MAC field on the RMEP is the same as the RMEP's MAC address on the MEP.
2. Perform the following steps on the MEP:
3. Collect alarm information and configuration information, and then contact technical support personnel.