MEP received a CCM with the Port Status TLV or Interface Status TLV reporting an error status. (MdIndex=[MdIndex], MaIndex=[MaIndex], MdName=[MdName], MaName=[MaName], MepId=[MepId], RmepId=[RmepId])
TLV information carried in a CCM sent by the RMEP within a specified interval showed that the interface connecting the RMEP to the MEP became abnormal.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
EXCEPTIONALMACSTATUS |
Trap OID |
1.3.6.1.4.1.2011.5.25.136.1.6.44 |
MIB |
HUAWEI-ETHOAM-MIB |
Alarm ID |
0x09ac000c |
Alarm Name |
EXCEPTIONALMACSTATUS |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
EOAM-1AG_1.3.6.1.4.1.2011.5.25.136.1.6.45 hwDot1agCfmExceptionalMACStatusCleared |
Parameter | Description |
---|---|
MdIndex |
Index of an MD table |
MaIndex |
Index of an MA table |
MdName |
Name of an MD |
MaName |
Name of an MA |
MepId |
ID of a MEP |
RmepId |
ID of an RMEP |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.136.1.1.3.2.1.3 |
hwDot1agCfmMdName |
hwDot1agCfmMdIndex |
1.3.6.1.4.1.2011.5.25.136.1.1.4.2.1.2 |
hwDot1agCfmMaName |
hwDot1agCfmMdIndex hwDot1agCfmMaIndex |
1.3.6.1.4.1.2011.5.25.136.1.1.5.1.1.1 |
hwDot1agCfmMepIdentifier |
hwDot1agCfmMdIndex hwDot1agCfmMaIndex hwDot1agCfmMepIdentifier |
1.3.6.1.4.1.2011.5.25.136.1.1.6.1.1.1 |
hwDot1agCfmRMepIdentifier |
hwDot1agCfmMdIndex hwDot1agCfmMaIndex hwDot1agCfmRMepIdentifier |
1. Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command on the RMEP to view the values of the Interface Name and Direction fields. Obtain the interface type and number and check the value of the Direction field.
2. Perform the following steps on the RMEP:
3. Run the display interface interface-type interface-number command to view the value of the current state field on the RMEP.
4. Perform the following steps on the RMEP:
5. Run the display stp brief command to view the value of the STP State field. The STP State field is related to the Interface Name field that shows the same interface type and number as those obtained in step 1.
6. Collect alarm information and configuration information, and then contact technical support personnel.