Error-down occurred. (Ifindex=[IfIndex], Ifname=[IfName], Cause=[Cause])
The alarm was generated when an errordown event occurred.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Warning |
Mnemonic Code |
hwErrordown |
Trap OID |
1.3.6.1.4.1.2011.5.25.257.2.1 |
MIB |
HUAWEI-ERRORDOWN-MIB |
Alarm ID |
0x08520006 |
Alarm Name |
hwErrordown |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
ERROR-DOWN_1.3.6.1.4.1.2011.5.25.257.2.2 hwErrordownRecovery |
Parameter | Description |
---|---|
IfIndex |
Index of an interface |
IfName |
Interface name |
Cause |
Cause of the errordown event |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.2.1.31.1.1.1.1 |
ifName |
ifIndex |
1.3.6.1.4.1.2011.5.25.257.1.1 |
hwErrordownCause |
- |
1. Check whether the interface should be specified as an edge port.
2. Run the undo stp edged-port and undo shutdown commands to remove the edge port configuration. Check whether the log exists. If the alarm persists, go to Step 3.
3. Collect alarm information and contact Huawei technical support personnel.
1. For how to handle the alarm when the upstream link of the Monitor Link group went Down, see IFNET_1.3.6.1.6.3.1.1.5.3 linkdown.
1. Identify the attack source and prevent the attacks. After the fault is rectified, run the shutdown and undo shutdown commands in the interface view to restore the service interface state.