In an EVPN E-Tree dual-homing scenario, the leaf attributes of the AC interfaces bound to the EVPN instance were different, causing a traffic loop. (EVPNInstanceName = [EVPNInstanceName], IfName = [IfName])
In an EVPN E-Tree scenario where a CE is dual-homed to PEs, the leaf attributes of the PEs' AC interfaces bound to the EVPN instance were different, causing a traffic loop.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
EVPN_ETREE_MULTIHOMED_CONFIG_ERROR |
Trap OID |
1.3.6.1.4.1.2011.5.25.356.1.1.2.3 |
MIB |
HUAWEI-EVPN-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
EVPNInstanceName |
EVPN instance name. |
IfName |
Interface name. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.356.1.1.1.1.1.1 |
hwEvpnInstanceVpnName |
hwEvpnInstanceVpnName |
1.3.6.1.4.1.2011.5.25.356.1.1.1.1.1.2 |
hwEvpnInstanceIfName |
hwEvpnInstanceVpnName |
1. Check whether the evpn e-tree-leaf command is run on both AC interfaces of the dual-homing PEs.
2. Collect log information and configuration information, and then contact technical support personnel.
3. End.