FEI_APS_1.3.6.1.4.1.2011.5.25.119.10.2.18 hwPwApsTunnelNonSupport

Trap Buffer Description

PW APS does not support the current public tunnel. (VcID=[VcID], VcType=[VcType], PeerAddr=[PeerAddr])

PW APS did not support the current public tunnel.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

hwPwApsTunnelNonSupport

Trap OID

1.3.6.1.4.1.2011.5.25.119.10.2.18

MIB

HUAWEI-L2VPN-PW-APS-MIB

Alarm ID

0x00F100ab

Alarm Name

hwPwApsTunnelNonSupport

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

FEI_APS_1.3.6.1.4.1.2011.5.25.119.10.2.19 hwPwApsTunnelNonSupportResumed

Trap Buffer Parameters

Parameter Description

VcID

ID of a VC

VcType

VC Type:

  • 1: FR
  • 2: ATM_AAL5
  • 3: ATM_CELL_TRANSPORT
  • 4: VLAN
  • 5: ETHERNET
  • 6: HDLC
  • 7: PPP
  • 8: CEM
  • 9: ATM_CELL_VCC
  • 10: ATM_CELL_VPC
  • 11: IP_LAYER2_TRANSPORT
  • 12: ATM_ONE_TO_ONE_VCC_CELL_MODE
  • 13: ATM_ONE_TO_ONE_VPC_CELL_MODE
  • 14: ATM_AAL5_PDU_VCC_TRANSPORT
  • 15: FR_PORT
  • 16: CEP
  • 17: SAT_E1_OVER_PACKET
  • 18: SAT_T1_OVER_PACKET
  • 19: SAT_E3_OVER_PACKET
  • 20: SAT_T3_OVER_PACKET
  • 21: CESOPSN_BASIC_MODE
  • 22: TDMOIP_AAL1
  • 23: CESOPSN_TDM
  • 24: TDMOIP_AAL2
  • 25: FR_DLCI
  • 26: INTERWORKING
  • 27: VPLS
  • 64: IP_INTERWORKING

PeerAddr

Peer IP address

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.119.9.1.3

hwL2vpnVcID

-

1.3.6.1.4.1.2011.5.25.119.9.1.4

hwL2vpnVcType

-

1.3.6.1.4.1.2011.5.25.119.9.1.5

hwL2vpnPeerAddr

-

Impact on the System

PW APS failed.

Possible Causes

The PW bound to the APS instance was carried over a non-TE tunnel.

Procedure

1.Check the bearer tunnel type of the PW. In a VLL scenario, run the display mpls l2vc command to check the bearer tunnel type; in a VPLS scenario, run the display vsi name command to check the bearer tunnel type.

  • If the tunnel is a TE tunnel, go to Step 3.
  • If the tunnel is a non-TE tunnel, go to Step 2.

2.Configure a TE tunnel as the bearer tunnel. Then, check whether the alarm persists.

  • If the alarm is cleared, go to Step 4.
  • If the alarm is persists, go to Step 3.

3.Collect trap, log, and configuration information, and contact technical support personnel.

4.End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
Next topic >