The total number of iFIT instances on the interface board reaches the upper limit. (Type=[Type],SlotId=[SlotId],FlowLimitNum=[FlowLimitNum])
The number of iFIT instances on the interface board reached the upper limit.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Warning |
Mnemonic Code |
hwIfitExceedInstanceThreshold |
Trap OID |
1.3.6.1.4.1.2011.5.25.364.2.1.5 |
MIB |
HUAWEI-IFIT-MIB |
Alarm ID |
0x00f103e8 |
Alarm Name |
hwIfitExceedInstanceThreshold |
Alarm Type |
qualityOfServiceAlarm |
Raise or Clear |
Raise |
Match trap |
FEI_IFIT_OM_1.3.6.1.4.1.2011.5.25.364.2.1.6 hwIfitExceedInstanceAlarmResume |
Parameter | Description |
---|---|
Type |
The Instance Type. |
SlotId |
The LPU Number. |
FlowLimitNum |
The Maximum number of iFIT Instances on this LC Board. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.364.1.5.1.1.1 |
hwIfitInstanceType |
hwIfitInstanceType hwIfitInstanceBoard hwIfitMaxInstanceInBoard |
1.3.6.1.4.1.2011.5.25.364.1.5.1.1.2 |
hwIfitInstanceBoard |
hwIfitInstanceType hwIfitInstanceBoard hwIfitMaxInstanceInBoard |
1.3.6.1.4.1.2011.5.25.364.1.5.1.1.3 |
hwIfitMaxInstanceInBoard |
hwIfitInstanceType hwIfitInstanceBoard hwIfitMaxInstanceInBoard |
iFIT instances of this type are no longer generated.
The out-of-order packet measurement function does not take effect for the new ingress iFIT out-of-order packet measurement instance on an interface board.
The out-of-order packet measurement function does not take effect for the new iFIT out-of-order packet measurement instance on the transit node's egress of the interface board.
The new automatic flow learning instance does not take effect on the interface board.
The new whitelist-based automatic flow learning instance does not take effect on the interface board.
New dummy instances are no longer generated on the interface board.
The new iFIT out-of-order instance function does not take effect on the interface board.
Reduce the number of iFIT instances of this type on the interface board.
The number of iFIT out-of-order measurement instances enabled on the upstream interface board of the ingress has been reduced.
The number of iFIT out-of-order measurement instances enabled on the interface board of the transit node's egress has been reduced.
Reduce the number of common automatic flow learning instances on the interface board.
Reduce the number of whitelist-based automatic flow learning instances on the interface board.
The number of dummy instances on the interface board is reduced.
The number of out-of-order iFIT instances on the interface board has been reduced.